Why absorbance cannot be more than 1




















The linearity of the Beer-Lambert law is limited by chemical and instrumental factors. Remember that absorbance is the logarithm of the transmission T of light through a sample. Transmission is the ratio of the intensity of light transmitted through the sample I to the intensity of light transmitted through a blank Io. Any absorbance reading above 1 can be inaccurate. What does absorbance value tell you? Absorbance is a measure of the quantity of light absorbed by a sample.

It is also known as optical density, extinction, or decadic absorbance. What is the unit for absorbance? What is the maximum absorbance value? What is Beer's Law equation? Beer's Law is an equation that relates the attenuation of light to properties of a material.

The law states that the concentration of a chemical is directly proportional to the absorbance of a solution. What causes absorbance to increase? According to this law, absorbance and concentration are directly proportional.

If you increase the original concentration, the absorbance increases and if you dilute the solution which means you decrease the original concentration , the absorbance will decrease in direct proportion.

The only difference is the molar absorptivities at the different wavelengths, so a spectrum represents a plot of the relative molar absorptivity of a species as a function of wavelength. Measuring the concentration of a species in a sample involves a multistep process.

One important consideration is the wavelength of radiation to use for the measurement. Remember that the higher the molar absorptivity, the higher the absorbance. What this also means is that the higher the molar absorptivity, the lower the concentration of species that still gives a measurable absorbance value. The second step of the process is to generate a standard curve. The standard curve is generated by preparing a series of solutions usually with known concentrations of the species being measured.

Every standard curve is generated using a blank. The blank is some appropriate solution that is assumed to have an absorbance value of zero. It is used to zero the spectrophotometer before measuring the absorbance of the standard and unknown solutions.

Assuming a linear standard curve is obtained, the equation that provides the best linear fit to the data is generated. If the path length is known, the slope of the line can then be used to calculate the molar absorptivity. The third step is to measure the absorbance in the sample with an unknown concentration. The absorbance of the sample is used with the equation for the standard curve to calculate the concentration.

The way to think about this question is to consider the expression we wrote earlier for the absorbance. Since stray radiation always leaks in to the detector and presumably is a fixed or constant quantity, we can rewrite the expression for the absorbance including terms for the stray radiation. At low concentration, not much of the radiation is absorbed and P is not that much different than P o.

If the sample is now made a little more concentrated so that a little more of the radiation is absorbed, P is still much greater than P S. As the concentration is raised, P, the radiation reaching the detector, becomes smaller. If the concentration is made high enough, much of the incident radiation is absorbed by the sample and P becomes much smaller.

At its limit, the denominator approaches P S , a constant. The ideal plot is the straight line. Spectroscopic instruments typically have a device known as a monochromator. There are two key features of a monochromator. The first is a device to disperse the radiation into distinct wavelengths. You are likely familiar with the dispersion of radiation that occurs when radiation of different wavelengths is passed through a prism. The term effective bandwidth defines the packet of wavelengths and it depends on the slit width and the ability of the dispersing element to divide the wavelengths.

The important thing to consider is the effect that this has on the power of radiation making it through to the sample P o. Reducing the slit width will lead to a reduction in P o and hence P. An electronic measuring device called a detector is used to monitor the magnitude of P o and P. All electronic devices have a background noise associated with them rather analogous to the static noise you may hear on a speaker and to the discussion of stray radiation from earlier that represents a form of noise.

P o and P represent measurements of signal over the background noise. As P o and P become smaller, the background noise becomes a more significant contribution to the overall measurement. Ultimately the background noise restricts the signal that can be measured and detection limit of the spectrophotometer. Therefore, it is desirable to have a large value of P o. Since reducing the slit width reduces the value of P o , it also reduces the detection limit of the device.

Selecting the appropriate slit width for a spectrophotometer is therefore a balance or tradeoff of the desire for high source power and the desire for high monochromaticity of the radiation. It is not possible to get purely monochromatic radiation using a dispersing element with a slit. Usually the sample has a slightly different molar absorptivity for each wavelength of radiation shining on it. The net effect is that the total absorbance added over all the different wavelengths is no longer linear with concentration.

Instead a negative deviation occurs at higher concentrations due to the polychromicity of the radiation. The Beer-Lambert law relates the attenuation of light to the properties of the material through which the light is traveling. This page takes a brief look at the Beer-Lambert Law and explains the use of the terms absorbance and molar absorptivity relating to UV-visible absorption spectrometry.

For each wavelength of light passing through the spectrometer, the intensity of the light passing through the reference cell is measured. The absorbance of a transition depends on two external assumptions. This formula is the common form of the Beer-Lambert Law , although it can be also written in terms of intensities:.

On most of the diagrams you will come across, the absorbance ranges from 0 to 1, but it can go higher than that. An absorbance of 0 at some wavelength means that no light of that particular wavelength has been absorbed. In a sample with an absorbance of 1 at a specific wavelength, what is the relative amount of light that was absorbed by the sample?

You will find that various different symbols are given for some of the terms in the equation - particularly for the concentration and the solution length.

The Greek letter epsilon in these equations is called the molar absorptivity - or sometimes the molar absorption coefficient.

The larger the molar absorptivity, the more probable the electronic transition. In uv spectroscopy, the concentration of the sample solution is measured in mol L -1 and the length of the light path in cm.

Thus, given that absorbance is unitless, the units of molar absorptivity are L mol -1 cm However, since the units of molar absorptivity is always the above, it is customarily reported without units. Guanosine has a maximum absorbance of nm. What is the concentration of guanosine? What is the extinction coefficient?

The proportion of the light absorbed will depend on how many molecules it interacts with. Suppose you have got a strongly colored organic dye.